二氧化碳储罐的定能特点
1. 安全运转:选用“组合、安全体系阀”运用两组安全阀一起作业,在安全阀定时校验时可封闭一侧,另一侧持续作业,保证储罐的安全运转。
3. 功能安稳牢靠:液态二氧化碳储罐具有功能安稳、操作保护便当、发动时间短、运转平稳等长处,产品全国。
二氧化碳储罐压力不能低于1.4MPa作业,二氧化碳液体在低于0.7MPa时会构成干冰,一旦构成干冰,储罐就很麻烦了,里边二氧化碳液体凝结成冰,将很难处理。
你所说的是二氧化碳储罐在运用过程中压力不断下降,为了避免不断下降压力,你如今需要添加一套二氧化碳子增压体系,此体系构成有两个有些;
为了维持低温情况,储罐有必要装备制冷机,当温度上升时,敞开制冷机,使二氧化碳储罐内温度下降到规划温度。在储罐上装备有压力表,一起为了便利用户运用,储罐上还装配了一台主动指示液面、称重计量的存量。
1、操作前的准备 Preparation before operation
【产品详情图片】
1.1 操作者应按本说明书要求及有关文件进行操作。The operator shall follow the instructions and related documents to operate.
1.2正式投入使用前,用干燥的CO2气体对整个系统进行吹除置换,吹除置换所用的气体纯度不低于充装介质的纯度。Formally put into use before the use of dry CO2 gas blowing the entire system replacement, purge replacement gas purity of not less than the purity of the filling
【产品详情图片】
【主变量】【变量3】【变量2】【变量1】
常见故障的处理 Common fault handling
【产品详情图片】
1.内罐压力异常长高 Inner tank pressure abnormally high
1.1可能是V3回气阀开度过大或阀门失灵,应减小阀门开度或检修阀门。
May be V3 return valve opening is too large or valve failure, should reduce the valve opening or valve repair.
1.2可能是S1、S2安全阀失灵,到启动压力不启动,应检查安全阀。
may be S1, S2 safety valve failure, to start the pressure does not start, check the safety valve.
1.3可能是压力表指示不准确,应校验压力表。
may be pressure gauge indicates inaccurate, should verify the pressure gauge.
2.液位计指示不真实 Level gauge instructions are not true
2.1可能是液位计失灵,应检修液位计。
may be the level gauge failure, should be maintenance level gauge
2.2可能是液位计接头处泄漏,应检修接头连接处,排除泄漏。
It may be a leak at the head of the liquid level gauge. It should repair the connection of the joint and eliminate the leakage
3.蒸发率高,外壳体凝水结霜 High evaporation rate, the outer condensate frost
3.1可能是珠光砂未填实或下沉,应补充珠光砂,重新抽真空。
may be unfilled or sinking of pearl sand, pearl sand should be added and re-evacuated.
3.2可能是真空度恶化,应进行真空检漏,重新抽真空。
may be a deterioration of the vacuum, vacuum leak detection should be carried out, re-vacuum.
4.管道阀门液体流动不畅或堵塞 pipeline valve fluid flow or blocked
可能是液体二氧化碳形成干冰的原因造成,应停止使用,用热空气加温管阀至畅通为止。May be caused by the formation of dry ice, should stop using, with hot air heating pipe valve until smooth.
2 储罐的操作Tank operation
【产品详情图片】
储罐的操作分为充液、贮存、增压、排液等过程,每个过程必须做到:V6三通截止阀(连接安全阀)和V8液位计组合阀始终处于全开状态。罐内压力不应高于2.16Mpa,压力不应低于0.8Mpa .
The operation of the tank is divided into filling, storage, pressurization, drainage and other processes, each process must be: V6 three-way valve (connecting safety valve) and V8 level gauge combination valve is always in the fully open state. Tank maximum pressure should not exceed 2.16Mpa, the minimum pressure should not be less than 0.8Mpa.
【产品详情图片】
【主变量】【变量3】【变量2】【变量1】
充液的操作 filling operation
【标题】
充液分为充液和补充充液。
充液的操作如下:
Filling fluid is divided into the first filling and filling fluid.
The first filling operation is as follows:
2.1.1 储罐吹除置换干净达到要求后,将充液管线与储罐的充液接头连接,液位计组合阀处于平衡状态准备充液。
After the tank blows off to replace the cleanliness meets the requirements, the filling liquid line is connected with the liquid filling joint of the tank, and the liquid level gauge combination valve is in an equilibrium state to be filled.
2.1.2充入与液体二氧化碳纯度相同的气体,使罐内压力达到0.8 Mpa以上,方可进行充液。 filled with the same purity of liquid carbon dioxide gas, the tank pressure reached 0.8 Mpa above, before filling.
2.1.3 将充液管线接通槽车,先开启V5残液阀,排出管线内的杂质气体后,再开启V1进液阀和V7排气阀,V8液位计组合阀处于全开状态,显示液位计读数进行充液。
The filling liquid line connected tanker, first open the V5 raffinate valve, exhaust gas impurities within the pipeline, and then open the V1 inlet valve and V7 exhaust valve, V8 level gauge combination valve is fully open state, Display level meter readings are filled.
2.1.4 在充液过程中,当液位计指示液位接近标定值时,可间断开启V4充满指示阀,如有液体喷出,应立即停止充液,关闭V4充满指示阀。
During the filling process, when the liquid level gauge indicates the liquid level approaches the calibration value, the V4 may be intermittently opened to indicate the valve. If any liquid is ejected, liquid filling should be stopped immediately and the V4 valve should be closed.
2.1.5关闭V1进液阀和V7排气阀,打开V5残液阀,拆下充液管线,充液结束。
补充充液的操作与充液的操作方法相似,不同点是补充充液时一开始就可以大量充液。
Close the V1 inlet valve and the V7 exhaust valve, open the V5 residual valve, remove the filling line, and fill with liquid.
The procedure for replenishing the priming solution is the same as for the first priming procedure, except that the priming solution can be replenished extensively from the beginning.
【产品详情图片】
【标题】
lng液化天然气储罐的使用注意事项
lng液化天然气加气站储罐的使用注意事项:
1、有双根部阀的储罐,靠近储罐则的阀门,应常开。
2、卸车时,建议储罐的限充装量为不超过有效容积的90%(厂家给出为几何容积的85%-95%),使用余量不能低于10%。
3、lng储罐压力高时,不一定为储罐有问题,应考虑整个系统的漏热和存液时间等情况,一般在压力超过1.1MPa时需进行排放泄压,储罐长时间处于高压状态会影响储罐夹层真空的寿命。
4、储罐出现大量的长时间的“冒汗”或结霜,且压力不停快速上涨时,应考虑其真空失效,应进行紧急处理,手动排压,转移罐内的LNG液体。
5、储罐建议每隔一年进行一次真空检测,储罐为热罐时真空度小于1Pa,储罐为冷罐时真空度为小于0.5Pa(0.00375TOF)为合格。
6、储罐不能带液运输,长时间停用时应排放掉罐内的LNG液体。
7、储罐属压力容器设备,根据中华共和国颁布实施的《压力容器安全技术监察规程》要求,安装、维修、改造压力容器,需有相应资质的单位到当地质检部门进行告知,获得许可后才能进行安装、维修、改造。
lng液化天然气储罐的使用注意事项
山东中杰股份有限公司,位于菏泽市开发区济南路2218号。公司共有厂区3处,总占地25万余平方米,主车间面积60000余平方米,员工1000多人,其中工程技术人员220余人。 公司高度聚焦绿色能源行业,主导产品有:燃油(气)锅炉、有机热载体炉、生物质锅炉、余热锅炉等锅炉产品;LNG储罐、氧氮氩储罐、CO2储罐等真空绝热深冷压力容器;液化石油气储罐、液氨储罐、脱硝工程设备、蓄热储能设备、成套化工设备等压力容器产品;地(水)源热泵、空气源机组、水冷螺杆机组、风冷模块等中央空调暖通设备,同时承接LPG液化气站安装、LNG标准站安装、锅炉安装、工业管道安装、化工设备安装等业务。公司规划产品有大型热能中心、LNG运输车、LNG罐式集装箱等绿色能源装备。公司销售网络广泛,先后为中国石油、中国石化、中国海油、中国燃气、中国中车、中国华冶、青岛啤酒、汇源果汁、金正大等两万多家大中型企业提品和技术服务,同时产品还出口到东南亚、中亚及非洲、拉丁美洲等国家和地区,销售,深受用户好评。公司拥有自营进出口权,具有B级锅炉制造许可及A2级压力容器制造许可资质,A2级压力容器设计许可资质,2级锅炉安装和GB2类、GC类压力管道安装许可资质及机电设备安装*,累计获得授权实用新型专利15项,授权发明专利2项,并通过了ISO9001质量管理体系、ISO14001环境管理体系和OHSAS18001职业健康安全管理体系认证,现已成为国家。历经多年积淀,企业已发展成为集团化、规模化、多元化的大型企业。公司下设燃气锅炉、导热油炉、深冷容器、压力容器、中央空调、工程安装和国际贸易7大事业中心,内部管理规范,职工餐厅、职工宿舍、职工班车等配套设施齐全,为各类人才搭建了没有天花板的广阔发展平台。山东中杰股份有限公司致力于绿色能源事业的发展,以的产品和服务奉献社会!选择中杰特装,携手共铸辉煌!