LH51索尼SONY磁栅显示器维修
DigitalReadouts:LG10,LH30,LH51,LH70
Linear Encoders:GB-ER,GB-A,MSS-101,SD-608,SJ-300,SJ-700,SJ300A,SL-110,SL220,SL-331,SL-700,SR-118,SR-127,SR-33/34SR-801
Digital Gauges:DE-BR,DG-10B,DG-110B,DG-50BDG-805,DG-MDK-802/812,DL-B,DL-BR,DR-12N,DR-32NV,DT-512,LT-10,LT-11LT-20LY-51LY-52LY-71/72MG-SeriesMT-10U-Series
Measuring Accessories:BD-95,MD-10,MD-20A,MD-21,MJ-100,MJ-500,MJ-620,MJ-820,MJ-830,PH-100,PL-101,PL-30,PL-80,PL-81,SET-B3,SET-P15
SONY数显表LG10系列:LG10-1、LG10-2、LG10-3
LH71A:LH71-1/LH71-2/LH71-3
以紧凑尺寸多样的选择,灵活对应车床用**显示单元。
车床的功能
较小表示量转换
区间误差校正
保存数据
复位/预置
测量原点检测单位
程序功能
缩放
车床式样(工具)坐标/加机能
电源另售AC适配器(PSC -21)是很必要的。
LH70/71
LH70/71 Display Counter Pricing
Model
Description
MSRP
LH70-1
Single Axis LH70 Display
$600.00
LH70-2
Two Axis LH70 Display
$710.00
LH70-3
Three Axis LH70 Display
$815.00
LH71-1
Single Axis LH71 Display
$700.00
LH71-2
Two Axis LH71 Display
$810.00
LH71-3
Three Axis LH71 Display
$915.00
DisplaySpecifications
Model Name
LH70-1
LH70-2
LH70-3
LH71-1
LH71-2
LH71-3
Item
Display Axes
1
2
3
1
2
3
Display
7 digits and "-" display. Amber LEDs
Connectable measuring Units
SJ300 Series (Direct).
GB-A/SR128, PL20B, DG-B Series (Adaptors Available)
Scale Input resolution
Basic: 0.1μm, 0.5μm, 5μm, 10μm, 1s, 10s, 1min, 10min
Expanded: 100μm, 50μm, 25μm, 20μm, 2μm, 0.05μm
Display resolution*
Basic: The above and their diamter displays
0.000005", 0.00001", 0.00002", 0.00005", 0.0001", 0.0002", 0.0005", and their diameter displays
Expanded: The above and their diamter displays
0.000002", 0.000005", 0.00001", 0.00002", 0.00005", 0.0001", 0.0002", 0.0005", 0.001", 0.002", 0.005 and their diameter displays
Input **
A/B Quadrature **, Z ** (Equivalent with RS-422)
Mh. phase input difference
100ns
Alarm display
Scale disconnected / Excess speed / Data Overflow / Power failure / Error in stored data
Preset/Recall function
3 items
Mulit datum point
10
150
Tool offsets (for Lathe)
-
12
-
99
Axis Summing
-
Same as LH71
-
Sum of 2 axes
Display Hold
-
Same as LH71
-
The displayed value can be held and the datum entered
Ref. point function
The absolute zero point can be detected and the datum point can be re-established. (Requires a scale with a reference point)
Bolt hole circle
-
Same as LH71
-
Input diamter, start angle, stop angle, No. of holes
Radius cutting function
-
Same as LH71
-
Input radius, Tool diameter, feed angle
Data storage
Stores the value dispalyed before power loss and the last preset datum
Max. linear error compensation
±600μm/m
4001.JPG4002.JPG4003.JPG4004.JPG4005.JPG